Čes. stomatol. Prakt. zub. lék. (Czech Dental Journal) 2001; 101(3): 81-88

Adhesion of Leucit-Enforced Glass Ceramics

Z. Mach, K. Hroníková, D. Houšová, J. Regent, L. Mrklas
Výzkumný ústav stomatologický, Praha, přednosta doc. MUDr. O. Krejsa, CSc.

The formation of overlap technique of prefabricated leucite reinforced glass-ceramic inlays carried new positives, but also problem with extension of bonded surfaces between luting material and inlays. Shear bond strength of this adhesive bond up to 12 months and after thermo-cycling, and microleakage after 24 hours were tested. Two micro-filled compositeluting cements (Panavia 21, All-Bond C&B) were used.

Keywords: glass-leucite ceramics; ceramics inserts; shear bond strength

Published: September 1, 2001  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Mach Z, Hroníková K, Houšová D, Regent J, Mrklas L. Adhesion of Leucit-Enforced Glass Ceramics. Čes. stomatol. Prakt. zub. lék. 2001;101(3):81-88.
Download citation

This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0), which permits non-comercial use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.