The study investigated the quality of surface of titanium implant model, covered by laser-deposed layer of hydroxyapatite with a zirconium inter-layer. The surface was evaluated in vitro, human line fibroblasts therefore colonized the surface and multiplied there without displaying morphological changes. The study evaluates the new material as a suitable one for implantation with possibilities of immediate production of prosthetic substitution.
Keywords: implant; hydroxyapatite; zirconium; ceramics; fibroblasts
Published: December 1, 2004 Show citation
ACS | AIP | APA | ASA | Harvard | Chicago | Chicago Notes | IEEE | ISO690 | MLA | NLM | Turabian | Vancouver |
This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0), which permits non-comercial use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.